Abstract:A new method for the simultaneous dissolution anddetermination of Tin and Silver in copper solder was reported.Thesample was dissolved with 2 g tartaric acid and 8 mL nitricacid,Tin and Silve were simultancously determined by ICP-AES,Therecoveries of the elements were in the range of 98%~102%,and theRSD 0.9%~2.1%.
Key words: Copper solder; Tin; Silver; Simultaneous Dissolution anddetermination;ICP-AES
近年來,錫銀合金被廣泛應(yīng)用在焊料行業(yè)中,目前對它們的檢測項目主要有滴定法和光譜法2種。在該合金分析中,樣品中錫銀的溶解是分析中最重要的步驟,目前常用的樣品溶解方法有:濃硫酸濃硝酸溶解錫銀①、王水溶解銅錫②③以及稀硝酸溶解錫。這3種方法無論是哪一種都不能同時溶解合金中的錫銀。在銅基錫銀焊料樣品中,含銀量都比較高,王水溶解法和濃硫酸濃硝酸法都無法全部能使樣品中銀溶解,故不能用王水和濃硫酸和濃硝酸處理;而稀硝酸不能溶解錫。基于以上幾個原因,我們要檢測焊料中的錫銀時,樣品分解要使用不同的溶解方法,分析過程繁瑣。本文研究了使用酒石酸和濃硝酸同時溶解銅錫銀合金中的錫和銀,最后用電感耦合等離子體發(fā)射光譜儀同時測定錫和銀④⑤。結(jié)果表明:此方法快速,準確。
1 實驗部分
1.1 儀器與實驗條件
單向觀測順序掃描型電感耦合等立體發(fā)射光譜儀(ICP-AES)ICP-2000天瑞儀器股份有限公司生產(chǎn),儀器工作條件:等離子體線圈功率:1.1KW,高壓:4KV,冷卻氣流量:18L/min,輔助氣流量0.5L/min,測定波長:銀:328.0,錫235.4。采用徑向觀測。
1.2試劑
硝酸 優(yōu)級純 500 mL /瓶 昆山晶科微電子材料有限公司
酒石酸 分析純 500 g/瓶 天津大茂化學試劑廠
超純水 實驗室一級用水 南京易普易達設(shè)備廠
1.3樣品處理
準確稱取0.050 g樣品于燒杯中,依次加入2.000 g酒石酸,5 mL去離子水和8mL濃硝酸,于100℃加熱板上溶解,完全后,冷卻,將溶液轉(zhuǎn)移到100 mL 容量瓶中,以水定容,再取10 mL到100mL容量瓶中,稀釋10倍待測。
1.4標液配置
分別吸取1000 mg/L銀,錫標液0.0、0.1、0.5、1.0 mL至100mL容量瓶中,加入2 g酒石酸以及5mL濃硝酸,去離子水定容.即得0.0、1.0、2.0、5.0、10.0 mg/L的銀錫混合溶液。
2結(jié)果與討論
2.1溶解樣品試劑用量實驗
若溶解錫銀,須用硝酸;本研究在固定硝酸用量的情況下,通過改變酒石酸的用量來考察樣品溶解效果。實驗結(jié)果表明:對加入0.0g,0.5g,1.0g,1.5g 4個不同質(zhì)量的酒石酸的錫銀焊料,樣品均不能完全溶解,酒石酸的最佳用量在2.0 g。
2.2 試劑加入順序
實驗表明,溶解樣品時首先加入酒石酸,將會保證硝酸完全溶解錫而不形成偏錫酸,同時硝酸溶解銀。
2.3樣品溶解溫度及溶解時間的影響
實驗表明,溶解溫度控制在150℃左右(見圖一),同時控制溶解時間(圖二),使溶液體積不要由于過多的蒸發(fā)引起晶體析出,本實驗選用的最佳溶解時間為15min左右。